DS1243Y
8 of 13
PHANTOM CLOCK AC ELECTRICAL
CHARACTERISTICS (0°C to 70°C; V
CC
= 4.5 to 5.5V)
PARAMETER SYMBOL MIN TYP MAX UNITS NOTES
Read Cycle Time t
RC
120 ns
CE
Access Time
t
CO
100 ns
OE
Access Time
t
OE
100 ns
CE
to Output Low Z
t
COE
10 ns
OE
to Output Low Z
t
OEE
10 ns
CE
to Output High Z
t
OD
40 ns 5
OE
to Output High Z
t
ODO
40 ns 5
Read Recovery t
RR
20 ns
Write Cycle Time t
WC
120 ns
Write Pulse Width t
WP
100 ns
Write Recovery t
WR
20 ns 10
Data Setup Time t
DS
40 ns 11
Data Hold Time t
DH
10 ns 11
CE
Pulse Width
t
CW
100 ns
RESET
Pulse Width
t
RST
200 ns
CE
High to Power-Fail
t
PF
0 ns
POWER-DOWN/POWER-UP TIMING
PARAMETER SYMBOL MIN TYP MAX UNITS NOTES
CE
at V
IH
before Power-Down
t
PD
0
µs
V
CC
Slew from 4.5V to 0V (
CE
at V
IH
)
t
F
300
µs
V
CC
Slew from 0V to 4.5V (
CE
at V
IH
)
t
R
0
µs
CE
at V
IH
after Power-Up
t
REC
2 ms
(t
A
= 25°C)
PARAMETER SYMBOL MIN TYP MAX UNITS NOTES
Expected Data Retention Time t
DR
10 years 9
WARNING:
Under no circumstances are negative undershoots, of any amplitude, allowed when device is in battery
backup mode.
Kommentare zu diesen Handbüchern