Note:
Some revisions of this device may incorporate deviations from published specifications known as errata. Multiple
revisions of any device may be simultaneously available through various sales
channels. For information about device
errata, click here: http://dbserv.maxim-ic.com/errata.cfm.
FEATURES
§ Records the total time that the event input has
been active and the number of events that
have occurred
§ 32-bit, nonvolatile, elapsed time counter
monitors event duration with quarter-second
resolution and provides 34 years of total time
accumulation
§ Programmable elapsed time
ALARM
output
§ Nonvolatile 17-bit event counter records the
total number of times an event has occurred
§ Calibrated, temperature-compensated RC
time base accurate to 2% typical
§ 10 bytes of EEPROM user memory
§ Write disable function to prevent the memory
from being changed or erased
§ 2-wire serial communication
§ Wide power-supply range (2.5V to 5.5V)
§ Useful in time-of-use warranty, calibration,
repair, and maintenance applications
PIN ASSIGNMENT
Package dimension information can be found at:
http://dbserv.maxim-ic.com/products.cfm
PIN DESCRIPTION
EVENT - Event Input
ALARM
- Alarm Output
GND - Ground
SDA - Serial-Data I/O
SCL - Serial-Clock Input
V
CC
- Voltage Supply
N/C - No Connect
ORDERING INFORMATION
DS1682S 8-Pin SO (150mil) -40°C to +85°C
DESCRIPTION
The DS1682 is an integrated elapsed time recorder containing a factory-calibrated, temperature-
compensated RC time base that eliminates the need for an external crystal. Using EEPROM technology
to maintain data in the absence of power, the DS1682 requires no backup power source. The DS1682
detects and records the number of events on the EVENT pin and the total cumulative event time since the
DS1682 was last reset to 0. The
ALARM
pin alerts the user when the total time accumulated equals the
user-programmed alarm value. The polarity of the open-drain
ALARM
pin can be programmed to either
drive low or to become high impedance upon an alarm condition. The DS1682 is ideal for applications
that monitor the total amount of time that a device has been in operation and/or the number of uses since
inception of service, repair, or the last calibration.
SDA
1
SCL
EVENT
6
3
2
GND
V
CC
8
4
5
7
N/C
N/C
ALARM
Top View
DS1682S 8-Pin SO (150mil)
DS1682
DS1682
Total Elapsed Time Recorder
with Alarm
www.maxim
-
ic.com
Seitenansicht 0
1 2 3 4 5 6 ... 14 15

Inhaltsverzeichnis

Seite 1 - Total Elapsed Time Recorder

1 of 15 041202 Note: Some revisions of this device may incorporate deviations from published specifications known as errata. Multiple revisio

Seite 2 - Figure 1. BLOCK DIAGRAM

DS1682 10 of 15 The DS1682 can operate in the following two modes: 1) Slave Receiver Mode (DS1682 Write Mode): Serial data and clock are received

Seite 3 - SIGNAL DESCRIPTIONS

DS1682 11 of 15 ABSOLUTE MAXIMUM RATINGS* Voltage Range on Any Pin Relative to Ground -0.3V to +6V Operating Temperature Range -40°C to +85°C

Seite 4 - Figure 2. MEMORY MAP

DS1682 12 of 15 AC ELECTRICAL CHARACTERISTICS (-40°C to +85°C; VCC = 2.5V to 5.5V) PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS NOTES EEPRO

Seite 5 - DEVICE SETUP

DS1682 13 of 15 Figure 7. TIMING DIAGRAM NOTES: 1) VCC must be at or above 2.5V for tEW after the end of an event to insure data transfer to th

Seite 6 - RESET COMMAND

DS1682 14 of 15 Figure 8. TOTAL RUN TIME Figure 8 shows the DS1682 measuring total run time and operating from a battery with the alarm tied to

Seite 7 - USER MEMORY

DS1682 15 of 15 Figure 10. TOTAL TIME-OF-USE APPLICATION WITH SLOW VCC SLEW RATE Figure 10 shows the DS1682 in a total time-of-use application wi

Seite 8 - 2-WIRE SERIAL DATA BUS

DS1682 2 of 15 OPERATION The block diagram in Figure 1 shows the relationship between the major functional blocks, the serial interface, and the EEP

Seite 9 - 9 of 15

DS1682 3 of 15 SIGNAL DESCRIPTIONS VCC – VCC is a +2.5V to +5.5V input supply. GND – Ground. SCL (2-Wire Serial-Clock Input) – The SCL pin is th

Seite 10

DS1682 4 of 15 Figure 2. MEMORY MAP ADDR BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 FUNCTION 00 0 AF WDF WMDF AOS RE AP ECMSB Configu

Seite 11 - 11 of 15

DS1682 5 of 15 EVENT LOGGING When the DS1682 is powered up, the event time and count values recorded in the EEPROM are transferred to the ETC and e

Seite 12 - = 2.5V to 5.5V)

DS1682 6 of 15 ALARM The alarm register is a 32-bit register that holds time in quarter-second resolution. When a nonzero number is programmed into

Seite 13 - Figure 7. TIMING DIAGRAM

DS1682 7 of 15 CONFIGURATION REGISTER MSb LSb 0 AF WDF WMDF AOS RE AP ECMSB Note: The configuration register is not stored in EEPROM until a

Seite 14 - SLEW RATE

DS1682 8 of 15 2-WIRE SERIAL DATA BUS The DS1682 supports a bidirectional, 2-wire bus and data-transmission protocol. A device that sends data onto

Seite 15

DS1682 9 of 15 Accordingly, the following bus conditions have been defined: Bus Not Busy: Both data and clock lines remain HIGH. Start Data Trans