MAX6854–MAX6869
Nanopower µP Supervisory Circuits with
Optional Manual Reset, Watchdog Timer
14 ______________________________________________________________________________________
RESET TIMEOUT PERIODS
TIMEOUT
OPTION
MIN TYP MAX
UNITS
D1 10 15 25
D2 40 60 80
D3 150 225 300
D4 1200 1800 2400
D5 300 450 600
D6 600 900 1200
ms
Table 4. Reset Timeout Periods
PART TOP MARK
MAX6854UK16D3 AEFS
MAX6854UK23D3 AEFY
MAX6854UK26D3 AEFZ
MAX6854UK29D3 AEGA
MAX6854UK31D3 AEGB
MAX6856UK16D3 AEGR
MAX6856UK23D3 AEGS
MAX6856UK26D3 AEGT
MAX6856UK29D3 AEGU
MAX6856UK31D3 AEGV
MAX6861UK17 AEKO
MAX6861UK225 AEKS
MAX6861UK26 AEKP
MAX6861UK29 AEKQ
MAX6862UK17 AEOS
MAX6862UK225 AEOT
MAX6862UK26 AEOU
MAX6862UK29 AEOV
MAX6863UK17 AEOW
MAX6863UK225 AEOX
MAX6863UK26 AEOY
MAX6863UK29 AEOZ
MAX6864UK16D3S AEGC
MAX6864UK23D3S AEGD
MAX6864UK26D3S AEGE
MAX6864UK29D3S AEGF
MAX6864UK31D3S AEGG
MAX6866UK16D3S AEGW
MAX6866UK23D3S AEGX
MAX6866UK26D3S AEGY
MAX6866UK29D3S AEFT
MAX6866UK31D3S AEGZ
Table 5. Standard Versions
Ordering Information (continued)
PART
TEMP RANGE
PIN-PACKAGE
MAX6856UK_ _D_-T*
-40°C to +85°C
5 SOT23-5
MAX6857UK_ _D_-T*
-40°C to +85°C
5 SOT23-5
MAX6858UK_ _D_-T*
-40°C to +85°C
5 SOT23-5
MAX6859UK_ _D_-T*
-40°C to +85°C
5 SOT23-5
MAX6860UK_ _D_-T*
-40°C to +85°C
5 SOT23-5
MAX6861UK_ _-T
-40°C to +85°C
5 SOT23-5
MAX6862UK_ _-T*
-40°C to +85°C
5 SOT23-5
MAX6863UK_ _-T*
-40°C to +85°C
5 SOT23-5
MAX6864UK_ _D_ _-T*
-40°C to +85°C
5 SOT23-5
MAX6865UK_ _D_ _-T*
-40°C to +85°C
5 SOT23-5
MAX6866UK_ _D_ _-T
-40°C to +85°C
5 SOT23-5
MAX6867UK_ _D_ _-T*
-40°C to +85°C
5 SOT23-5
MAX6868UK_ _D_ _-T*
-40°C to +85°C
5 SOT23-5
MAX6869UK_ _D_ _-T*
-40°C to +85°C
5 SOT23-5
Insert reset threshold suffix (see Table 2, Threshold Suffix
Guide) after UK. Insert the number corresponding to the desired
reset timeout period (see Table 4, Reset Timeout Period) after
“D.” Insert the letter corresponding to the desired watchdog
timeout period (S or L, see Table 3) into the blank following the
reset timeout period suffix for the MAX6864–MAX6869.
Note: Sample stock is generally held on standard versions
only (see Table 5, Standard Versions Table). Standard versions
have an order increment of 2500 pieces. Nonstandard versions
have an order increment of 10,000 pieces. Contact factory for
availability of nonstandard versions.
*Future product—Contact factory for availability.
Seitenansicht 13
1 2 ... 9 10 11 12 13 14 15 16 17

Kommentare zu diesen Handbüchern

Keine Kommentare