MAX13234E–MAX13237E
3Mbps RS-232 Transceivers with
Low-Voltage Interface
______________________________________________________________________________________ 11
Table 1. Transceiver Mode Control
FORCEOFF
FORCEON
R_IN or T_IN
EDGE WITHIN 30s
T_OUT R_OUT TRANSCEIVER STATUS
0X X
High-Impedance
Active Shutdown (Forced Off)
1 1 X Active Active Normal Operation (Forced On)
1 0 Yes Active Active
Normal Operation in AutoShutdown Plus
10 No
High-Impedance
Active Shutdown in AutoShutdown Plus
X = Don’t Care.
R_IN
T_IN
R
S
30s
TIMER
EDGE
DETECT
EDGE
DETECT
FORCEOFF
FORCEON
POWERDOWN*
AUTOSHDN
FORCEOFF
FORCEON
* POWERDOWN IS ONLY AN INTERNAL SIGNAL.
IT CONTROLS THE OPERATIONAL STATUS OF
THE TRANSMITTERS AND THE POWER SUPPLIES.
Figure 6. AutoShutdown Plus and Shutdown Logic