MAX9392/MAX9393
Anything-to-LVDS Dual 2 x 2
Crosspoint Switches
_______________________________________________________________________________________ 7
t
PHL
t
PLH
80%
20%
20%
80%
50% V
OD
= 0
V
OD
= 0
V
ID
= 0
V
OD
= 0
V
OD
= 0
V
ID
= 0
50%
V
ID
= V
IN_ _
- V
IN_ _
V
OD
= V
OUT_ _
- V
OUT_ _
t
PLH
AND t
PHL
MEASURED FOR ANY COMBINATION OF _SEL0 AND _SEL1.
V
IN_ _
V
IHD
V
ILD
V
IN_ _
V
OUT_ _
V
OUT_ _
t
F
t
R
V
IHD
V
ILD
V
IHD
V
ILD
V
IH
V
IL
V
OD
= 0
t
SWITCH
t
SWITCH
IN_0
IN_0
IN_1
IN_1
V
ID
= 0
V
ID
= 0
_SEL_
1.5V
IN_1
OUT_ _
OUT_ _
EN_0 = EN_1 = HIGH
V
ID
= V
IN_ _
- V
IN_ _
IN_0 IN_0
1.5V
V
OD
= 0
V
ID
= V
IN_ _
- V
IN_ _
V
OD
= V
OD
- V
OD
*
V
OS
= V
OS
- V
OS
*
V
OD
AND V
OS
ARE MEASURED WITH V
ID
= +100mV
V
OD
* AND V
OS
*
ARE MEASURED WITH V
ID
= -100mV
IN_ _
IN_ _
R
L
/2
R
L
/2
V
OD
OUT_ _
OUT_ _
1/4 MAX9392/MAX9393
EN_ _ = HIGH
V
OS
Figure 1. Output Transition Time and Propagation Delay Timing
Diagram
Figure 3. Input to Rising/Falling Edge Select and Mux Switch Timing Diagram
Figure 2. Test Circuit for V
OD
and V
OS
Seitenansicht 6