Absolute Maximum Ratings (Notes1&2)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales
Office/Distributors for availability and specifications.
Supply Voltage (V
CC
) (Note 3) 6.5V
Logic Control Inputs
b
0.3V to
a
18V
Voltage at Other Inputs and Outputs
b
0.3V to (V
CC
a
0.3V)
Storage Temperature Range
b
65
§
Cto
a
150
§
C
Package Dissipation at T
A
e
25
§
C 875 mW
Lead Temp. (Soldering, 10 seconds) 300
§
C
ESD Susceptibility (Note 10) 800V
Operating Conditions (Notes1&2)
Temperature Range T
MIN
s
T
A
s
T
MAX
ADC1001CCJ
b
40
§
C
s
T
A
s
a
85
§
C
ADC1001CCJ-1 0
§
C
s
T
A
s
a
70
§
C
Range of V
CC
4.5 V
DC
to 6.3 V
DC
Converter Characteristics
Converter Specifications: V
CC
e
5V
DC
,V
REF
/2
e
2.500 V
DC
,T
MIN
s
T
A
s
T
MAX
and f
CLK
e
410 kHz unless otherwise specified.
Parameter Conditions MIn Typ Max Units
Linearity Error
g
1 LSB
Zero Error
g
2 LSB
Full-Scale Error
g
2 LSB
Total Ladder Resistance (Note 9) Input Resistance at Pin 9 2.2 4.8 KX
Analog Input Voltage Range (Note 4) V(
a
)orV(
b
) GND
b
0.05 V
CC
a
0.05 V
DC
DC Common-Mode Error Over Analog Input Voltage Range
g
(/8 LSB
Power Supply Sensitivity V
CC
e
5V
DC
g
5% Over
g
(/8 LSB
Allowed V
IN
(
a
) and V
IN
(
b
)
Voltage Range (Note 4)
AC Electrical Characteristics
Timing Specifications: V
CC
e
5V
DC
and T
A
e
25
§
C unless otherwise specified.
Symbol Parameter Conditions MIn Typ Max Units
T
c
Conversion Time (Note 5) 80 90 1/f
CLK
f
CLK
e
410 kHz 195 220 ms
f
CLK
Clock Frequency (Note 8) 100 1260 kHz
Clock Duty Cycle 40 60 %
CR Conversion Rate In Free-Running INTR tied to WR with 4600 conv/s
Mode CS
e
0V
DC
,f
CLK
e
410 kHz
t
W(WR)L
Width of WR Input (Start Pulse CS
e
0V
DC
(Note 6) 150 ns
Width)
t
ACC
Access Time (Delay from C
L
e
100 pF 170 300 ns
Falling Edge of RD
to Output
Data Valid)
t
1H
,t
0H
TRI-STATE
É
Control (Delay C
L
e
10 pF, R
L
e
10k 125 200 ns
from Rising Edge of RD
to (See TRI-STATE Test
Hi-Z State) Circuits)
t
WI
,t
RI
Delay from Falling Edge 300 450 ns
of WR
or RD to Reset of INTR
t
1rs
INTR to 1st Read Set-Up Time 550 400 ns
C
IN
Input Capacitance of Logic 5 7.5 pF
Control Inputs
C
OUT
TRI-STATE Output 5 7.5 pF
Capacitance (Data Buffers)