As a result, the analog input impedance is relatively
constant over the input voltage as shown in Figure 5.
Single-ended conversions are internally referenced to
AGND1 (Tables 3 and 4). In differential mode, IN+ and
IN- are selected according to Tables 3 and 5. When con-
figuring differential channels, the differential pair follows
the analog configuration byte for the positive channel.
For example, to configure CH2 and CH3 for a ±V
REF
dif-
ferential conversion, set the CH2 analog configuration
byte for a differential conversion with the ±V
REF
range
(1010 1100). To initiate a conversion for the CH2 and
CH3 differential pair, issue the command 1010 0000.
Analog Input Bandwidth
The MAX1302/MAX1303 input-tracking circuitry has a
1.5MHz small-signal bandwidth. The 1.5MHz input band-
width makes it possible to digitize high-speed transient
events. Harmonic distortion increases when digitizing
signal frequencies above 15kHz as shown in the THD, -
SFDR vs. Analog Input Frequency plot in the Typical
Operating Characteristics.
Analog Input Range and Fault Tolerance
Figure 7 illustrates the software-selectable single-
ended analog input voltage range that produces a valid
digital output. Each analog input channel can be inde-
pendently programmed to one of seven single-ended
input ranges by setting the R[2:0] control bits with
DIF/SGL = 0.
MAX1302/MAX1303
8-/4-Channel, ±V
REF
Multirange Inputs,
Serial 16-Bit ADCs
______________________________________________________________________________________ 15
CS
SCLK
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
DIN S C2 C1 C0 0 0 0 0
ANALOG INPUT
TRACK AND HOLD*
DOUT
B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 B0
BYTE 1 BYTE 2 BYTE 3 BYTE 4
SSTRB
HOLD TRACK HOLD
HIGH
IMPEDANCE
t
ACQ
HIGH
IMPEDANCE
*TRACK AND HOLD TIMING IS CONTROLLED BY SCLK.
f
SAMPLE
f
SCLK
/ 32
SAMPLING INSTANT
Figure 2. External Clock-Mode Conversion (Mode 0)