Rainbow-electronics MAX1362 Bedienungsanleitung Seite 13

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 24
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 12
To generate a not-acknowledge condition, the receiver
allows SDA to be pulled high before the rising edge of
the acknowledge-related clock pulse, and leaves SDA
high during the high period of the clock pulse.
Monitoring the acknowledge bits allows for detection of
unsuccessful data transfers. An unsuccessful data
transfer happens if a receiving device is busy or if a
system fault has occurred. In the event of an unsuc-
cessful data transfer, the bus master reattempts com-
munication at a later time.
Slave Address
The MAX1361/MAX1362 have a 7-bit I
2
C slave
address. The slave address is selected using A0. The
MAX1361/MAX1362 (EUB, MEUB, and LEUB) have 3
base address options, allowing up to 6 devices concur-
rently per I
2
C bus (see Table 1).
The MAX1361/MAX1362 continuously wait for a START
condition followed by its slave address. When the device
recognizes its slave address, it is ready to accept or
send data depending on the R/W bit (Figure 6).
HS I
2
C Mode
At power-up, the MAX1361/MAX1362 bus timing is set
for fast mode (F/S mode, up to 400kHz I
2
C clock), which
limits the conversion rate to approximately 22ksps.
Switch to high-speed mode (HS mode, up to 1.7MHz
I
2
C clock) to achieve conversion rates up to 94.4ksps.
The MAX1361/MAX1362 convert up to 150ksps in moni-
tor mode, regardless of I
2
C mode. If conversion results
are unread, I
2
C bandwidth limitations do not apply in
monitor mode.
Select HS mode by addressing all devices on the bus
with the HS-mode master code 0000 1XXX (X = don’t
care). After successfully receiving the HS-mode master
code, the MAX1361/MAX1362 issue a NACK, allowing
SDA to be pulled high for one clock cycle (Figure 7).
After the NACK, the MAX1361/MAX1362 operate in HS
mode. Send a repeated START (Sr) followed by a slave
address to initiate HS-mode communication. If the mas-
ter generates a STOP condition the MAX1361/MAX1362
MAX1361/MAX1362
4-Channel, 10-Bit, System Monitor with Programmable
Trip Window and SMBus Alert Response
______________________________________________________________________________________ 13
011 1000R/WACK
SLAVE ADDRESS
S
SCL
SDA
123456789
Figure 6. MAX1361/MAX1362 Slave Address Byte
A0 STATE SUFFIX ADDRESS
Low EUB 0110100
High EUB 0110101
Low MEUB 0110110
High MEUB 0110111
Low LEUB 0110010
High LEUB 0110011
Table 1. I
2
C Slave Selection Table
000 10XXXNACK
HS-MODE MASTER CODE
SCL
SDA
S Sr
F/S MODE HS MODE
Figure 7. F/S-Mode to HS-Mode Transfer
Seitenansicht 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 23 24

Kommentare zu diesen Handbüchern

Keine Kommentare