4 _______________________________________________________________________________________
ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= +3.3V, configuration byte register = X8h, T
A
= -55°C to +125°C, unless otherwise noted.) (Note 5)
Note 1: Guaranteed, but not 100% tested.
Note 2: A remote diode is any diode-connected transistor from Table 7. T
R
is the junction temperature of the remote diode. See
Remote Diode Selection for remote-diode forward voltage requirements. Temperature specification guaranteed for a diode
with ideality factor (M
TR
= 1.013). Additional error = (1.013/M - 1)
✕
273 + Temp where M = Ideality of remote diode used.
Note 3: The SMBus logic block is a static design that works with clock frequencies down to DC. While slow operation is possible, it
violates the 10kHz minimum clock frequency and SMBus specifications and may monopolize the bus.
Note 4: Note that a transition must internally provide at least a hold time to bridge the undefined region (300ns max) of SMBCLK’s
falling edge.
Note 5: Specifications from -55°C to +125°C are guaranteed by design, not production tested.
CONDITIONS UNITSMIN TYP MAXPARAMETER
V
CC
= 3.0V 2.2
STBY, SMBCLK, SMBDATA
Input High Voltage
V
2.4
ALERT forced to 0.4V
mA1
ALERT Output Low Sink Current
V
CC
= 5.5V
V
CC
= 3.0V to 5.5V 0.8
STBY, SMBCLK, SMBDATA
Input Low Voltage
V
Logic inputs forced to V
CC
or GND -2 2
STBY, SMBCLK, SMBDATA
Input Current
µA
SMBCLK, SMBDATA forced to 0.6V 6
SMBCLK, SMBDATA Output
Low Sink Current
mA
ALERT forced to 5.5V
µA1
ALERT Output High Leakage