Rainbow-electronics MAX1989 Bedienungsanleitung Seite 4

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 16
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 3
0
8
4
16
12
20
24
MAX1668/1805 toc03
FREQUENCY (MHz)
TEMPERATURE ERROR (°C)
TEMPERATURE ERROR
vs. SUPPLY NOISE FREQUENCY
100mV
P-P
0.1 1 10 100
WITH V
CC
0.1µF CAPACITOR REMOVED
2200pF BETWEEN DXN_ AND DXP_
250mV
P-P
20
-20
1 10 100
TEMPERATURE ERROR
vs. PC BOARD RESISTANCE
-10
MAX1668/1805 toc01
LEAKAGE RESISTANCE (M)
TEMPERATURE ERROR (°C)
0
10
PATH = DXP_ TO GND
PATH = DXP_ TO V
CC
(5V)
-2
-1
0
1
2
3
4
-50 -10-30 10 30 50 70 90 110
TEMPERATURE ERROR
vs. TEMPERATURE
MAX1668/1805 toc02
TEMPERATURE (°C)
TEMPERATURE ERROR (°C)
NPN (CMPT3904)
PNP (CMPT3906)
INTERNAL
Typical Operating Characteristics
(Typical Operating Circuit, V
CC
= +5V, STBY = V
CC
, configuration byte = X0XXXX00, T
A
= +25°C, unless otherwise noted.)
MAX1668/MAX1805/MAX1989
Multichannel Remote/Local
Temperature Sensors
4 _______________________________________________________________________________________
ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= +5V, STBY = V
CC
, configuration byte = X0XXXX00, T
A
= -55°C to +125°C, unless otherwise noted.) (Note 6)
Note 1: Guaranteed by design, but not production tested.
Note 2: Quantization error is not included in specifications for temperature accuracy. For example, if the MAX1668/MAX1805/
MAX1989 device temperature is exactly +66.7°C, the ADC may report +66°C, +67°C, or +68°C (due to the quantization
error plus the +0.5°C offset used for rounding up) and still be within the guaranteed ±1°C error limits for the +60°C to
+100°C temperature range. See Table 2.
Note 3: A remote diode is any diode-connected transistor from Table 1. T
R
is the junction temperature of the remote diode. See the
Remote-Diode Selection section for remote-diode forward-voltage requirements.
Note 4: The SMBus logic block is a static design that works with clock frequencies down to DC. While slow operation is possible, it
violates the 10kHz minimum clock frequency and SMBus specifications, and can monopolize the bus.
Note 5: Note that a transition must internally provide at least a hold time in order to bridge the undefined region (300ns max) of
SMBCLK’s falling edge t
HD:DAT.
Note 6: Specifications from -55°C to +125°C are guaranteed by design, not production tested.
CONDITIONS UNITSMIN TYP MAXPARAMETER
STBY, SMBCLK, SMBDATA; V
CC
= 4.5V to 5.5V
Logic Input High Voltage V2.4
ALERT forced to 5.5V
µA1
ALERT Output High Leakage
Current
Logic inputs forced to V
CC
or GND µA-2 +2Logic Input Current
ALERT, SMBDATA forced to 0.4V
mA6Logic Output Low Sink Current
STBY, SMBCLK, SMBDATA; V
CC
= 4.5V to 5.5V
V0.8Logic Input Low Voltage
SMBus INTERFACE
Seitenansicht 3
1 2 3 4 5 6 7 8 9 ... 15 16

Kommentare zu diesen Handbüchern

Keine Kommentare