MAX4880
Overvoltage-Protection Controller with
Internal Disconnect Switch
_______________________________________________________________________________________ 3
Note 1: All devices are 100% tested at T
A
= +25°C. Electrical limits over the full temperature range are guaranteed by design.
ELECTRICAL CHARACTERISTICS (continued)
(V
IN
= 5V, T
A
= -40°C to +85°C, unless otherwise noted. Typical values are at T
A
= +25°C.) (Note 1)
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
FLAGV Assertion Delay t
FLAGV
V
IN
increasing from 5V to 8V at 3V/µs,
V
FLAGV
= 0.4V (Figure 2)
5.8 µs
Initial Overvoltage Fault Delay t
OVP
V
IN
increasing from 0 to 8V,
I
GATE
= 80% of I
PD
(Figure 3)
100
ns
Disable Time t
DIS
V
EN
= 2.4V, V
GATE
= 0.3V (Figure 4)
580
ns
EN, CB INPUTS
Input-High Voltage V
IH
1.4 V
Input-Low Voltage V
IL
0.5 V
Input Leakage A
FLAGV, BAT_OK OUTPUTS
Output Voltage Low V
OL
I
SINK
= 1mA, FLAGV, BAT_OK assert 0.4 V
Leakage Current V
BAT_OK
= V
FLAGV
= 5.5V 1 µA
THERMAL PROTECTION
Thermal Shutdown
+150
°C
Thermal Hysteresis 40 °C
Typical Operating Characteristics
(V
IN
= 5V, T
A
= +25°C, otherwise noted.)
I
IN
+ I
BTA
CURRENT vs. INPUT VOLTAGE
INPUT VOLTAGE (V)
I
IN
+ I
BTA
CURRENT (μA)
MAX4880 toc01
0 5 10 15 20 25 30
0
50
100
150
200
250
300
350
400
V
EN
= 0
V
CB
= 5V
OVLO TRIP POINT
UVLO TRIP POINT
I
IN
+ I
BTA
CURRENT vs. TEMPERATURE
TEMPERATURE (°C)
I
IN
+ I
BTA
CURRENT (μA)
MAX4880 toc02
-40 -15 10 35 60 85
0
50
100
150
200
250
300
350
400
GATE VOLTAGE vs. INPUT VOLTAGE
INPUT VOLTAGE (V)
GATE VOLTAGE (V)
MAX4880 toc03
012345678
0
3
6
9
12
UVLO TRIP POINT
OVLO TRIP POINT
Seitenansicht 2