MAX4978–MAX4981
Overvoltage Protector with
Active Current Limit
_______________________________________________________________________________________ 3
ELECTRICAL CHARACTERISTICS (continued)
(V
IN
= 5.0V, V
EN
= 0V, T
A
= -40°C to +85°C, unless otherwise noted. Typical values are at T
A
= +25°C.) (Note 2)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Thermal-Shutdown Hysteresis 10 °C
EN Input High Voltage V
IH
1.5 V
EN Input Low Voltage V
IL
0.6 V
EN Input Leakage Current I
LKGE
V
EN
= 5.5V or 0V -1 +1 µA
SDT Output Low Voltage V
OL
MAX4978/MAX4979, I
SINK
= 20mA 1 V
SDT Leakage Current I
LKGS
MAX4978/MAX4979, V
SDT
= 28V, SDT
deasserted
1µA
DYNAMIC (Note 3)
IN Debounce Time t
DEB
V
UVLO
< V
IN
< V
OVLO
to charge-pump
enable, Figure 1
120 160 200 ms
Switch Turn-On Time t
ON
Time from V
OUT
= 10% of V
IN
to V
OUT
= 90%
of V
IN
, R
L
= 10Ω, C
L
= 10µF
1.5 ms
Switch Turn-Off Time t
OFF
V
IN
< V
UVLO
or V
IN
> V
OVLO
to internal
switch off, R
L
= 1kΩ
515µs
Current-Limit Blanking Time t
BLANK
Short circuit applied, Figure 1 15 20 25 ms
Current-Limit Reaction Time t
REAC
Short circuit applied 5 µs
Overcurrent Autoretry Time t
RETRY
Figure 1 120 160 200 ms
Note 2: All devices are 100% production tested at T
A
= +25°C. Specifications over -40°C to +85°C are guaranteed by design.
Note 3: All timing is measured using 10% and 90% levels, unless otherwise noted.