Temperature-Window Alarm
The MAX6507 and MAX6508 have an output (OK, OK)
that indicates the die temperature is within the selected
temperature window. This output is asserted when
within the window, and deasserted when outside the
window. Additionally, a second digital output indicates
when the die temperature is above the upper set point.
This is useful in systems where operation is optimized
over a predetermined temperature range. The thermal
overrange signal can be used to assert a thermal shut-
down, power-up, recalibration, or other temperature-
dependent function (Figure 4 and Typical Operating
Circuits).
Chip Information
TRANSISTOR COUNT: 796
PROCESS: BiCMOS
TRIP TEMPERATURE (°C) HEX CODE*
-40 82
-35 87
-30 8C
-25 91
-20 96
-15 9B
-10 A0
-5 A5
000
505
10 0A
15 0F
20 14
25 19
30 1E
35 23
40 28
45 2D
50 32
55 37
60 3C
65 41
70 46
75 4B
80 50
85 55
90 5A
95 5F
100 64
105 69
110 6E
115 73
120 78
125 7D
MAX6505–MAX6508
Dual Trip SOT Temperature Switches
8 _______________________________________________________________________________________
Table 4. MAX6507/MAX6508 Trip
Temperature Code
*Two hex codes are used in the suffix. The first indicates the
the low trip temperature and the second indicates the high trip
temperature. For example, the MAX6507UT8255-T has a lower
trip point of -40°C and an upper trip point of +85 °C.
+2.5V TO +5.5V
OUT OF RANGE
SHUTDOWN
S0
OVER
GND
V
CC
OK
MAX6508
Figure 4. Temperature-Window Alarms