MAX6622
5-Channel Precision Temperature Monitor
______________________________________________________________________________________ 13
Table 7. Status 1 Register
BIT NAME
POR
STATE
FUNCTION
7 (MSB) Reserved 0 —
6 Local ALERT 0
Local Channel High-Alert Bit. This bit is set to logic 1 when the local
temperature exceeds the temperature threshold limit in the local ALERT high-
limit register.
5 Reserved 0 —
4 Reserved 0 —
3 Remote 4 ALERT 0
Channel 4 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the
channel 4 remote-diode temperature exceeds the temperature threshold limit
in the remote 4 ALERT high-limit register.
2 Remote 3 ALERT 0
Channel 3 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the
channel 3 remote-diode temperature exceeds the programmed temperature
threshold limit in the remote 3 ALERT high-limit register.
1 Remote 2 ALERT 0
Channel 2 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the
channel 2 remote-diode temperature exceeds the temperature threshold limit
in the remote 2 ALERT high-limit register.
0 Remote 1 ALERT 0
Channel 1 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the
channel 1 remote-diode temperature exceeds the temperature threshold limit
in the remote 1 ALERT high-limit register.
BIT NAME
POR
STATE
FUNCTION
7 (MSB) Reserved 0 —
6 Reserved 0 —
5 Reserved 0 —
4 Reserved 0 —
3 Remote 4 OVERT 0
Channel 4 Remote-Diode Overtemperature Status Bit. This bit is set to logic 1
when the channel 4 remote-diode temperature exceeds the temperature
threshold limit in the remote 4 OVERT high-limit register.
2 Reserved 0 —
1 Reserved 0 —
0 Remote 1 OVERT 0
Channel 1 Remote-Diode Overtemperature Status Bit. This bit is set to logic 1
when the channel 1 remote-diode temperature exceeds the temperature
threshold limit in the remote 1 OVERT high-limit register.
Table 8. Status 2 Register