MAX6641
SMBus-Compatible Temperature Monitor with
Automatic PWM Fan-Speed Controller
_______________________________________________________________________________________ 3
Note 1: Timing specifications guaranteed by design.
Note 2: The serial interface resets when SMBCLK is low for more than t
TIMEOUT
.
Note 3: A transition must internally provide at least a hold time to bridge the undefined region (300ns max) of SMBCLK’s falling edge.
ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= +3.0V to +5.5V, T
A
= 0°C to +125°C, unless otherwise noted. Typical values are at V
CC
= 3.3V, T
A
= +25°C.)
SMBus-COMPATIBLE TIMING (Note 1) (See Figures 2, 3)
Serial Clock Frequency f
SCLK
(Note 2) 100 kHz
Clock Low Period t
LOW
10% to 10% 4 µs
Clock High Period t
HIGH
90% to 90% 4.7 µs
Bus Free Time Between Stop and
Start Condition
t
BUF
4.7 µs
Hold Time After (Repeated) Start
Condition
t
HD:STA
S M Bus S tar t C ond i ti on S etup Ti m e
t
SU:STA
90% of SMBCLK to 90% of SMBDATA 4.7 µs
Start Condition Hold Time
t
HD:STO
10% of SMBDATA to 10% of SMBCLK 4 µs
Stop Condition Setup Time
t
SU:STO
90% of SMBCLK to 10% of SMBDATA 4 µs
Data Setup Time
t
SU:DAT
10% of SMBDATA to 10% of SMBCLK 250 ns
Data Hold Time
t
HD:DAT
10% of SMBCLK to 10% of SMBDATA
(Note 3)
300 ns
SMBus Fall Time t
F
300 ns
SMBus Rise Time t
R
1000
t
TIMEOUT
29 37 55 ms
Startup Time After POR t
POR
500 ms
Typical Operating Characteristics
(V
CC
= 3.3V, T
A
= +25°C, unless otherwise noted.)
OPERATING SUPPLY CURRENT
vs. SUPPLY VOLTAGE
MAX6641 toc01
SUPPLY VOLTAGE (V)
OPERATING SUPPLY CURRENT (µA)
5.04.54.03.5
350
400
450
500
550
600
300
3.0 5.5
NO SMBus ACTIVITY
REMOTE TEMPERATURE ERROR
vs. REMOTE-DIODE TEMPERATURE
MAX6641 toc02
TEMPERATURE (°C)
TEMPERATURE ERROR (°C)
1007525 50
-1.5
-1.0
-0.5
0
0.5
1.0
1.5
2.0
-2.0
0125
LOCAL TEMPERATURE ERROR
vs. DIE TEMPERATURE
MAX6641 toc03
TEMPERATURE (°C)
TEMPERATURE ERROR (°C)
100755025
-1
0
1
2
-2
0125