Rainbow-electronics MAX6696 Bedienungsanleitung Seite 3

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 20
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 2
MAX6695/MAX6696
Dual Remote/Local Temperature Sensors with
SMBus Serial Interface
_______________________________________________________________________________________ 3
ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= +3.0V to +3.6V, T
A
= 0°C to +125°C, unless otherwise noted. Typical values are at V
CC
= +3.3V and T
A
= +25°C)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
INPUT PIN, RESET, STBY (MAX6696)
Logic Input Low Voltage V
IL
0.8 V
Logic Input High Voltage V
IH
2.1 V
Input Leakage Current I
LEAK
-1 +1 µA
SMBus INTERFACE (SMBCLK, SMBDATA, STBY)
Logic Input Low Voltage V
IL
0.8 V
Logic Input High Voltage V
IH
2.1 V
Input Leakage Current I
LEAK
V
IN
= GND or V
CC
±1 µA
Output Low Sink Current I
OL
V
OL
= 0.6V 6 mA
Input Capacitance C
IN
5pF
SMBus-COMPATIBLE TIMING (Figures 4 and 5) (Note 2)
Serial Clock Frequency f
SCL
10 100 kHz
Bus Free Time Between STOP
and START Condition
t
BUF
4.7 µs
Repeat START Condition Setup
Time
t
SU:STA
90% of SMBCLK to 90% of SMBDATA 4.7 µs
START Condition Hold Time
t
HD:STA
10% of SMBDATA to 90% of SMBCLK 4 µs
STOP Condition Setup Time
t
SU:STO
90% of SMBCLK to 90% of SMBDATA 4 µs
Clock Low Period t
LOW
10% to 10% 4 µs
Clock High Period t
HIGH
90% to 90% 4.7 µs
Data Setup Time
t
SU:DAT
250
µs
Data Hold Time
t
HD:DAT
300
µs
SMB Rise Time t
R
s
SMB Fall Time t
F
300 ns
SMBus Timeout SMBDATA low period for interface reset 20 30 40 ms
Note 1: Based on diode ideality factor of 1.008.
Note 2: Specifications are guaranteed by design, not production tested.
Seitenansicht 2
1 2 3 4 5 6 7 8 ... 19 20

Kommentare zu diesen Handbüchern

Keine Kommentare