Rainbow-electronics AT77C104B Bedienungsanleitung Seite 14

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 36
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 13
14
AT77C104B
5347B–BIOM–08/04
Enctrl Register Register Name:Enctrl (7 bits)
Access Type:Read/Write
Function:Interrupts control
CLICKEN: click interrupts enable
0: default
1: click IRQ enabled
IRQ is generated when a click is detected.
MOVEN: movement interrupts enable
0: default
1: movement IRQ enabled
IRQ is generated when an X or Y movement is detected.
TRANSITEN: not used, for testing only
SLICEN: not used, for testing only
READERREN: read error interrupts enable
0: default
1: read error IRQ enabled
IRQ is generated when a read error is detected.
Note: The interrupt is cleared after the status register is read.
Heatctrl Register Register Name:Heatctrl (7 bits)
Access Type:Read/Write
Function:Heating control
HEAT: sensor heating
0: default, no heating
1: heating
The default value is recommended to optimize power consumption.
WDOGEN: watchdog enable
0: default
1: watchdog enabled
Watchdog automatically stops heating of the sensor after a time-out.
b6 b5 b4 b3 b2 b1 b0
CLICKEN MOVEN TRANSITEN SLICEN READERREN
0000000
b6 b5 b4 b3 b2 b1 b0
HEAT WDOGEN HEATV (MSB) HEATV(LSB)
0000000
Seitenansicht 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 35 36

Kommentare zu diesen Handbüchern