Rainbow-electronics AT84AD004 Bedienungsanleitung Seite 51

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 58
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 50
51
AT84AD004
5390A–BDC–06/04
Figure 54. Single-ended Termination Method for Clock I or Clock Q
Output Termination in
1:1 Ratio
When using the integrated DMUX in 1:1 ratio, the valid port is port A. Port B remains
unused.
Port A functions in LVDS mode and the corresponding outputs (DOAI or DOAQ) have to
be 100 differentially terminated as shown in Figure 55 on page 52.
The pins corresponding to Port B (DOBI or DOBQ pins) must be left floating (in high
impedance state).
Figure 55 on page 52 is an example of a 1:1 ratio of the integrated DMUX for channel I
(the same applies to channel Q).
CLK
CLKB
50
50
VCCD
R1
R2
VCCD/2
AC coupling capacitor
AC coupling capacitor
50
Source
50
Seitenansicht 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 57 58

Kommentare zu diesen Handbüchern

Keine Kommentare