LM19
2.4V, 10µA, TO-92 Temperature Sensor
General Description
The LM19 is a precision analog output CMOS integrated-
circuit temperature sensor that operates over a −55˚C to
+130˚C temperature range. The power supply operating
range is +2.4 V to +5.5 V. The transfer function of LM19 is
predominately linear, yet has a slight predictable parabolic
curvature. The accuracy of the LM19 when specified to a
parabolic transfer function is
±
2.5˚C at an ambient tempera-
ture of +30˚C. The temperature error increases linearly and
reaches a maximum of
±
3.8˚C at the temperature range
extremes. The temperature range is affected by the power
supply voltage. At a power supply voltage of 2.7 V to 5.5 V
the temperature range extremes are +130˚C and −55˚C.
Decreasing the power supply voltage to 2.4 V changes the
negative extreme to −30˚C, while the positive remains at
+130˚C.
The LM19’s quiescent current is less than 10 µA. Therefore,
self-heating is less than 0.02˚C in still air. Shutdown capa-
bility for the LM19 is intrinsic because its inherent low power
consumption allows it to be powered directly from the output
of many logic gates or does not necessitate shutdown at all.
Applications
n Cellular Phones
n Computers
n Power Supply Modules
n Battery Management
n FAX Machines
n Printers
n HVAC
n Disk Drives
n Appliances
Features
n Rated for full −55˚C to +130˚C range
n Available in a TO-92 package
n Predictable curvature error
n Suitable for remote applications
Key Specifications
j
Accuracy at +30˚C
±
2.5 ˚C (max)
j
Accuracy at +130˚C & −55˚C
±
3.5 to
±
3.8 ˚C (max)
j
Power Supply Voltage Range +2.4V to +5.5V
j
Current Drain 10 µA (max)
j
Nonlinearity
±
0.4 % (typ)
j
Output Impedance 160 (max)
j
Load Regulation
A
<
I
L
<
+16 µA −2.5 mV (max)
Typical Application
Output Voltage vs Temperature
20004002
V
O
= (−3.88x10
−6
xT
2
) + (−1.15x10
−2
xT) + 1.8639
or
where:
T is temperature, and V
O
is the measured output voltage of the LM19.
20004024
FIGURE 1. Full-Range Celsius (Centigrade) Temperature Sensor (−55˚C to +130˚C)
Operating from a Single Li-Ion Battery Cell
January 2003
LM19 2.4V, 10µA, TO-92 Temperature Sensor
© 2003 National Semiconductor Corporation DS200040 www.national.com
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1 - Typical Application

LM192.4V, 10µA, TO-92 Temperature SensorGeneral DescriptionThe LM19 is a precision analog output CMOS integrated-circuit temperature sensor that opera

Seite 2 - Ordering Information

Typical Application (Continued)Temperature (T) Typical VO+130˚C +303 mV+100˚C +675 mV+80˚C +919 mV+30˚C +1515 mV+25˚C +1574 mV0˚C +1863.9 mV−30˚C +220

Seite 3 - Electrical Characteristics

Absolute Maximum Ratings (Note 1)Supply Voltage +6.5V to −0.2VOutput Voltage (V++ 0.6 V) to−0.6 VOutput Current 10 mAInput Current at any pin (Note 2)

Seite 4 - 1.0 LM19 Transfer Function

Electrical Characteristics (Continued)Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings

Seite 5 - 3.0 Capacitive Loads

1.0 LM19 Transfer Function (Continued)2.0 MountingThe LM19 can be applied easily in the same way as otherintegrated-circuit temperature sensors. It ca

Seite 6 - 4.0 Applications Circuits

3.0 Capacitive Loads (Continued)4.0 Applications Circuits2000401620004033R(Ω) C (µF)200 1470 0.1680 0.011 k 0.001FIGURE 5. LM19 with Filter for Noisy

Seite 7 - 20004028

4.0 Applications Circuits (Continued)20004028Most CMOS ADCs found in ASICs have a sampled data comparator input structure that is notorious for causin

Seite 8

Physical Dimensions inches (millimeters) unless otherwise noted3-Lead TO-92 Plastic Package (Z)Order Number LM19CIZNS Package Number Z03ALIFE SUPPORT