Command Register
Three 32-bit command registers are used to configure
the MAX13362 for various modes of operation and are
accessed by the SPI-compatible interface (see Table 2).
LH_: Switch Configuration for IN0–IN3 and IN23
The LH0–LH3 and LH23 bits set the switch configuration
for IN0–IN3 and IN23, respectively. Set LH_ to 0 to con-
figure the input channel to ground connected. Set LH_
to1 to configure the input channel to battery connected.
The default configuration after power-on is LH_ = 0,
ground connected.
P0–P3: Polling Time
P0–P3 are used to set the polling time as shown in Table 3.
PA0–PA2: Polling Active Time
PA0–PA2 are used to set the polling active time as
shown in Table 4.
MAX13362
24-Channel Automotive Switch Monitor
______________________________________________________________________________________ 11