AT Commands Reference Guide
80000ST10025a Rev. 5 - 09/07/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 377 of 434
#CSURV - Network Survey SELINT 0 / 1
2
3
<rac> - routing area code
0..255 -
<spgc> - SPLIT_PG_CYCLE support
..0 - SPLIT_PG_CYCLE is not supported on CCCH on this cell
..1 - SPLIT_PG_CYCLE is supported on CCCH on this cell
<pat> - priority access threshold
0 -
3..6 -
<nco> - network control order
0..2 -
<t3168> - timer 3168
<t3192> - timer 3192
<drxmax> - discontinuous reception max time (in seconds)
<ctrlAck> - packed control ack
<bsCVmax> - blocked sequenc countdown max value
<alpha> - alpha parameter for power control
<pcMeasCh> - type of channel which shall be used for downlink
measurements for power control
0 - BCCH
1 - PDCH
(For non BCCH-Carrier)
arfcn: <arfcn> rxLev: <rxLev>
where:
<arfcn> - RF channel
<rxLev> - receiption level (in dBm)
Lastly, the #CSURV output ends in two ways, depending on the last
#CSURVF setting:
if #CSURVF=0 or #CSURVF=1
The output ends with the string:
Network survey ended
if #CSURVF=2
the output ends with the string:
Network survey ended (Carrier: <NoARFCN> BCCh: <NoBCCh>)
where
<NoARFCN> - number of scanned frequencies
<NoBCCH> - number of found BCCh