MAX4995A/AF/AL/MAX4995B/MAX4995C
50mA to 600mA Programmable
Current-Limit Switches
8 _______________________________________________________________________________________
continues beyond the blanking time. Reset the switch
by either toggling the control logic (ON) or cycling the
input voltage. If the thermal power rating of the pack-
age is exceeded during t
BLANK
, the MAX4995B goes
into thermal shutdown.
Continuous Current Limit (MAX4995C)
When the forward current reaches the forward current-
limit threshold, the MAX4995C limits the output current
to the programmed current limit. FLAG asserts if the
current limit is present for t
BLANK
and deasserts when
the overload condition is removed. In this mode, if the
thermal power rating of the package is exceeded, the
MAX4995C goes into thermal shutdown.
Switch-On/Off Control
The ON input for the MAX4995_/MAX4995AF and ON
input for the MAX4995AL control the switch; see Table
1. Toggle ON for the MAX4995B to reset the fault condi-
tion once the short current is detected and the device
shuts down.
Reverse-Current Protection
The MAX4995 features a reverse-current protection cir-
cuit that limits the backflow current to 10µA when the
output voltage exceeds the input voltage by 110mV
(typ). The switch turns off and FLAG asserts without
waiting for t
BLANK
to elapse. The switch turns back on
and FLAG deasserts when the output voltage drops
below the detecting threshold by 10mV (typ).
N.C.
*( ) FOR THE MAX4995AL ONLY.