MAX4995A/AF/AL/MAX4995B/MAX4995C
50mA to 600mA Programmable
Current-Limit Switches
_______________________________________________________________________________________ 9
FLAG
Indicator
FLAG is an open-drain fault indicator output and requires
an external pullup resistor to a DC supply. FLAG goes
low when any of the following conditions occurs:
• The device is in current-limit mode.
• The OUT voltage is above the IN voltage by more
than 110mV (typ).
• The die temperature exceeds the thermal-shutdown
temperature limit of +150°C.
• SETI is connected to ground.
Thermal Shutdown
Thermal-shutdown circuitry protects the devices from
overheating. The switch turns off and FLAG goes low
immediately when the junction temperature exceeds
+150°C (typ). The switch turns on again after the device
temperature drops by approximately 15°C (typ).