Rainbow-electronics ATmega64L Bedienungsanleitung Seite 168

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 298
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 167
168
ATmega16(L)
2466B09/01
Figure 83. Arbitration between Two Masters
Note that arbitration is not allowed between:
A REPEATED START condition and a data bit
A STOP condition and a data bit
A REPEATED START and a STOP condition
It is the user softwares responsibility to ensure that these illegal arbitration conditions
never occur. This implies that in multi-master systems, all data transfers must use the
same composition of SLA+R/W and data packets. In other words: All transmissions
must contain the same number of data packets, otherwise the result of the arbitration is
undefined.
SDA from
Master A
SDA from
Master B
SDA Line
Synchronized
SCL Line
START
Master A Loses
Arbitration, SDA
A
SDA
Seitenansicht 167