Rainbow-electronics DS1620 Bedienungsanleitung Seite 8

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 13
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 7
DS1620
8 of 13
DS1620 COMMAND SET Table 3
INSTRUCTION DESCRIPTION PROTOCOL
3-WIRE BUS
DATA AFTER
ISSUING
PROTOCOL NOTES
TEMPERATURE CONVERSION COMMANDS
Read Temperature Reads last converted temperature
value from temperature register.
AAh <read data>
Read Counter Reads value of count remaining
from counter.
A0h <read data>
Read Slope Reads value of the slope
accumulator.
A9h <read data>
Start Convert T Initiates temperature conversion. EEh Idle 1
Stop Convert T Halts temperature conversion. 22h Idle 1
THERMOSTAT COMMANDS
Write TH Writes high temperature limit value
into TH register.
01h <write data> 2
Write TL Writes low temperature limit value
into TL register.
02h <write data> 2
Read TH Reads stored value of high
temperature limit from TH register.
A1h <read data> 2
Read TL Reads stored value of low
temperature limit from TL register.
A2h <read data> 2
Write Config Writes configuration data to
configuration register.
0Ch <write data> 2
Read Config Reads configuration data from
configuration register.
ACh <read data> 2
NOTES:
1. In continuous conversion mode, a Stop Convert T command will halt continuous conversion. To
restart, the Start Convert T command must be issued. In one–shot mode, a Start Convert T command
must be issued for every temperature reading desired.
2. Writing to the E
2
typically requires 10 ms at room temperature. After issuing a write command no
further writes should be requested for at least 10 ms.
Seitenansicht 7
1 2 3 4 5 6 7 8 9 10 11 12 13

Kommentare zu diesen Handbüchern

Keine Kommentare