DS1624
14 of 16
AC ELECTRICAL CHARACTERISTICS (-55°C to +125°C; V
DD
=2.7V to 5.5V)
PARAMETERS SYMBOL CONDITION MIN TYP MAX UNITS NOTES
Temperature
Conversion Time
T
TC
400 1000 ms
NV Write Cycle
Time
t
WR
0°C to 70°C 10 50 ms 9
SLK Clock
Frequency
f
SCL
Fast Mode
Standard Mode
0
0
400
100
KHz
Bus Free Time
Between a
STOP and START
Condition
t
BUF
Fast Mode
Standard Mode
1.3
4.7
µs
Hold Time
(Repeated)
START Condition
t
HD:STA
Fast Mode
Standard Mode
0.6
4.0
µs 5
Low Period of
SCL Clock
t
LOW
Fast Mode
Standard Mode
1.3
4.7
µs
High Period of
SCL Clock
t
HIGH
Fast Mode
Standard Mode
0.6
4.0
µs
Setup Time for a
Repeated
START Condition
t
SU:STA
Fast Mode
Standard Mode
0.6
4.7
µs
Data Hold Time t
HD:DAT
Fast Mode
Standard Mode
0
0
0.9 µs 6
Data Setup Time t
SU:DAT
Fast Mode
Standard Mode
100
250
ns 7
Rise Time of both
SDA and
SCL Signals
t
R
Fast Mode
Standard Mode
20+0.1C
B
300
1000
ns 8
Fall Time of both
SDA and
SCL Signals
t
F
Fast Mode
Standard Mode
20+0.1C
B
300
300
ns 8
Setup Time for
STOP
Condition
t
SU:STO
Fast Mode
Standard Mode
0.6
4.0
µs
Capacitive Load
for each Bus
Line
C
b
400 pF
All values referred to V
IH
=0.9 V
DD
and V
IL
=0.1 V
DD
.
Kommentare zu diesen Handbüchern