Rainbow-electronics MAX1611 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Sensoren Rainbow-electronics MAX1611 herunter. Rainbow Electronics MAX1611 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 20
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
16
15
14
13
12
11
10
9
1
2
3
4
5
6
7
8
BATT
LX
BST
GND
VL
CS
OTP
REF
UP
DN
SHDN
SYNC
SS
CC
CSAV
MINDAC
TOP VIEW
MAX1610
SO
MAX1610/MAX1611
Digitally Controlled CCFL Backlight
Power Supplies
________________________________________________________________
Maxim Integrated Products
1
19-1128; Rev 0; 9/96
EVALUATION KIT
AVAILABLE
For free samples & the latest literature: http://www.maxim-ic.com, or phone 1-800-998-8800
_______________General Description
The MAX1610/MAX1611 are fully integrated, high-
efficiency drivers for cold-cathode fluorescent lamps
(CCFLs). They operate from a 4.5V to 26V power
source. An on-board, high-switching-frequency power
MOSFET reduces external component count and mag-
netics size. The MAX1610/MAX1611 protect against
open or shorted lamps. The CCFL can be driven from
an isolated transformer secondary winding to improve
efficiency and avoid flicker at dim tube settings.
Brightness is adjusted by scaling the lamp current, or
by operating with a fixed lamp current and chopping
the CCFL on and off at a rate faster than the eye can
detect.
The MAX1610’s digital inputs increment, decrement, or
clear an internal, 5-bit up/down counter, which sets
CCFL brightness. The MAX1611 uses a System
Management Bus (SMBus) 2-wire serial interface to
directly set CCFL brightness. Both devices include
micropower shutdown and a linear regulator that elimi-
nates the need for a separate logic supply. The digital
interface remains active in shutdown, preserving the
brightness setting.
________________________Applications
Notebook/Laptop Computers
Point-of-Sale Terminals
Portable Medical Equipment
Instrument Displays
____________________________Features
Direct Digital Control of CCFL Brightness
Low Supply Current: 3mA Max Operating
20µA Max Shutdown
Low-Voltage Operation, Down to 4.5V
Internal 26V, 0.7 Power Switch
Protection Against Open or Shorted Lamps
Supports Isolated Transformer Secondary
Winding
SMBus Serial Interface (MAX1611)
No Flicker at Low Brightness (internal 280Hz
current chopping)
High Power-to-Light Efficiency
Selectable 290kHz/145kHz Switching Frequency
Oscillator SYNC Input
16-Pin Narrow SO Package
16
15
14
13
12
11
10
9
1
2
3
4
5
6
7
8
BATT
LX
BST
GND
VL
CS
OTP
REF
SDA
SCL
SMBSUS
SYNC
SS
CC
CSAV
MINDAC
MAX1611
SO
__________________________________________________________Pin Configurations
PART
MAX1610CSE
MAX1611CSE
0°C to +70°C
0°C to +70°C
TEMP. RANGE PIN-PACKAGE
16 Narrow SO
16 Narrow SO
______________Ordering Information
Seitenansicht 0
1 2 3 4 5 6 ... 19 20

Inhaltsverzeichnis

Seite 1 - Power Supplies

16151413121110912345678BATTLXBSTGNDVLCSOTPREFUPDNSHDNSYNCSSCCCSAVMINDACTOP VIEWMAX1610SOMAX1610/MAX1611Digitally Controlled CCFL Backlig

Seite 2

MAX1610/MAX1611Digitally Controlled CCFL Backlight Power Supplies10 __________________________________________________________________________________

Seite 3

MAX1610/MAX1611Digitally Controlled CCFL Backlight Power Supplies_____________________________________________________________________________________

Seite 4

MAX1610/MAX1611Digitally Controlled CCFL Backlight Power Supplies12 __________________________________________________________________________________

Seite 5

MAX1610/MAX1611Digitally Controlled CCFL Backlight Power Supplies_____________________________________________________________________________________

Seite 6

MAX1610/MAX1611switching frequency. Any rising edge on SYNC restartsa BATT-to-LX switch cycle by forcing the switch on.________MAX1610 Digital Interfa

Seite 7

MAX1610/MAX1611Digitally Controlled CCFL Backlight Power Supplies_____________________________________________________________________________________

Seite 8

NAME DESCRIPTION7 REGSELRegister Select. A zero in this bit writes the remaining seven bits into the 7-bit latch-0(Figure 13).6 SHDNB-0Complete Shutdo

Seite 9

two 7-bit registers is used. Tables 4 and 5 describe thedata format for the configuration data.Status information can be read from the MAX1611using th

Seite 10

MAX1610/MAX1611minimum 9% duty cycle. DAC code 00000 shuts off thelamp entirely (0% duty cycle). Figure 14 shows thechopped waveforms with the DAC set

Seite 11

MAX1610/MAX1611Digitally Controlled CCFL Backlight Power Supplies_____________________________________________________________________________________

Seite 12

MAX1610/MAX1611Digitally Controlled CCFL Backlight Power Supplies2 ___________________________________________________________________________________

Seite 13

MAX1610/MAX1611Digitally Controlled CCFL Backlight Power SuppliesMaxim cannot assume responsibility for use of any circuitry other than circuitry enti

Seite 14

MAX1610/MAX1611Digitally Controlled CCFL Backlight Power Supplies_____________________________________________________________________________________

Seite 15

MAX1610/MAX1611Digitally Controlled CCFL Backlight Power Supplies4 ___________________________________________________________________________________

Seite 16

MAX1610/MAX1611Digitally Controlled CCFL Backlight Power Supplies_____________________________________________________________________________________

Seite 17

MAX1610/MAX1611Digitally Controlled CCFL Backlight Power Supplies6 ___________________________________________________________________________________

Seite 18

MAX1610/MAX1611Digitally Controlled CCFL Backlight Power Supplies_____________________________________________________________________________________

Seite 19

_______________Detailed DescriptionGetting StartedA cold-cathode fluorescent lamp (CCFL) has two termi-nals. For the CCFL to emit light, the two lamp

Seite 20

MAX1610/MAX1611Digitally Controlled CCFL Backlight Power Supplies_____________________________________________________________________________________

Kommentare zu diesen Handbüchern

Keine Kommentare