Rainbow-electronics MAX1611 Bedienungsanleitung Seite 4

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 20
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 3
MAX1610/MAX1611
Digitally Controlled CCFL Backlight
Power Supplies
4 _______________________________________________________________________________________
Note 1: Guaranteed by design.
TIMING CHARACTERISTICS—MAX1611
(Figures 2 and 3, T
A
= +25°C, unless otherwise noted.)
(Note 1)
(Note 1)
CONDITIONS
µs
1t
R
SCL, SCA Rise Time
µs
4.7t
LOW
µs
4t
HIGH
SCL Serial Clock High Period
SCL Serial Clock Low Period
ns
500t
SU:DAT
SDA Valid to SCL Rising Edge
Setup Time, Slave Clocking in Data
µs
0.3t
F
SCL, SDA Fall Time
µs
4.7t
SU:STA
Start Condition Setup Time
µs
4t
HD:STA
Start Condition Hold Time
UNITSMIN TYP MAXSYMBOLPARAMETER
µs
1t
DV
SCL Falling Edge to SDA Valid,
Reading Out Data
(Note 1) ns0t
HD:DAT
SCL Falling Edge to SDA
Transition
TIMING CHARACTERISTICS—MAX1610
(Figure 1, T
A
= +25°C, unless otherwise noted.)
CONDITIONS
µs
1t
3
UP, DN Pulse Separation
µs
1t
2
µs
1t
1
UP, DN Pulse Width High
UP, DN Pulse Width Low
µs
1t
4
Counter Reset Time
UNITSMIN TYP MAXSYMBOLPARAMETER
Seitenansicht 3