Rainbow-electronics MAX1619 Bedienungsanleitung Seite 13

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 20
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 12
MAX1619
Remote/Local Temperature Sensor with Dual-
Alarm Outputs and SMBus Serial Interface
______________________________________________________________________________________ 13
Table 4. Command-Byte Bit Assignments
*
If the device is in hardware standby mode at POR, both temperature registers read 0°C.
Read remote temperature: returns latest temperatureRRTE 01h
00h
COMMAND
0000 0000*
0000 0000*
POR STATE
Read configuration byteRCL 03h
02h
0000 1100
N/A Read status byte (flags, busy signal)RSL
Read remote T
MAX
limitRRTM 10h
Read local temperature: returns latest temperatureRLTS
04h
01100100
0000 0010
Read remote T
HIGH
limitRRHI 07h
11h
0111 1111
01011111 Read remote T
HYST
limitRRTH
Read conversion rate byte
REGISTER
RCRA
Write configuration byteWCA 09h
08h
N/A
1100 1001
FUNCTION
Write remote T
MAX
limitWRTM 12h
0Ah
N/A
N/A Write conversion rate byteWCRW
Write remote T
HIGH
limitWRHA 0Dh
Read remote T
LOW
limitRRLS
13h
N/A
N/A
One-shot command OSHT 0Fh
0Eh
N/A
N/A Write remote T
LOW
limitWRLN
Write remote T
HYST
limitWRTH
RUN/
STOP
6 0
0
POR STATE
Standby mode control bit. If high, the device immediately stops converting and
enters standby mode. If low, the device converts in either one-shot or timer
mode.
Masks all ALERT interrupts when high.
FUNCTION
POL5 0
Determines the polarity of the OVERT output:
0 = active low (low when overtemp)
1 = active high
MASK7 (MSB)
BIT NAME
Table 5. Configuration-Byte Bit Assignments
Write addressWADD FDh
FCh
N/A
N/A
Read device ID codeDEV ID FFh
FEh
0000 0100
0100 1101 Read manufacturer ID codeMFG ID
Write software PORSPOR
PROT4 0
When asserted high, locks out all subsequent writes to:
[] Configuration register bits 6, 5, 4, 3, 2 (RUN/STOP, POL, PROT, ID1, ID2)
[] T
MAX
register
[] T
HYST
register
[] Conversion rate register
[] Diode Current
ID13 1 Reduces the diode current by 5µA when set low.
ID22 1 Reduces the diode current by 2.5µA when set low.
RFU1–0 0 Reserved for future use.
Seitenansicht 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 19 20

Kommentare zu diesen Handbüchern

Keine Kommentare