MAX5510/MAX5511
+1.8V to +5.5V, Ultra-Low-Power, 8-Bit,
Voltage-Output DACs
______________________________________________________________________________________ 13
CONTROL BITS INPUT DATA SUB-BITS
C3
C2 C1
C0 D7–D0 S3–S0
FUNCTION
0000 XXXXXXXX 0000 No operation; command is ignored.
0001 8-bit data 0000
Load input register from shift register; DAC register
unchanged; DAC output unchanged.
0010 ——Command reserved; do not use.
0011 ——Command reserved; do not use.
0100 ——Command reserved; do not use.
0101 ——Command reserved; do not use.
0110 ——Command reserved; do not use.
0111 ——Command reserved; do not use.
1000 8-bit data 0000
Load DAC register from input register; DAC output
updated; MAX5510 enters normal operation if in
shutdown; MAX5511 enters normal operation if in
standby or shutdown.
1001 8-bit data 0000
Load input register and DAC register from shift register;
DAC output updated; MAX5510 enters normal operation
if in shutdown; MAX5511 enters normal operation if in
standby or shutdown.
1010 ——Command reserved; do not use.
1011 ——Command reserved; do not use.
1100
D7, D6,
XXXXXX
0000
MAX5510 enters shutdown; MAX5511 enters standby*.
For the MAX5511, D7 and D6 configure the internal
reference voltage (Table 3).
1101
D7, D6,
XXXXXX
0000
MAX5510/MAX5511 enter normal operation; DAC output
reflects existing contents of DAC register. For the
MAX5511, D7 and D6 configure the internal reference
voltage (Table 3).
1110
D7, D6,
XXXXXX
0000
MAX5510/MAX5511 enter shutdown; DAC output set to
high impedance. For the MAX5511, D7 and D6 configure
the internal reference voltage (Table 3).
1111 8-bit data 0000
Load input register and DAC register from shift register;
DAC output updated; MAX5510 enters normal operation
if in shutdown; MAX5511 enters normal operation if in
standby or shutdown.
Table 2. Serial-Interface Programming Commands
X = Don’t care.
*Standby mode can be entered from normal operation only. It is not possible to enter standby mode from shutdown.