WatchDog Programming The three lower bits (S0, S1, S2) located into WDTPRG register permit to program the
WDT duration.
Table 43. Machine Cycle Count
To compute WD Time-Out, the following formula is applied:
Note: Svalue represents the decimal value of (S2 S1 S0)
The following table indicates the computed Time-Out value for Fosc
XTAL
=12MHzinX1
mode
Table 44. Time-Out Computation
S2 S1 S0 Machine Cycle Count
000 2
14
-1
001 2
15
-1
010 2
16
-1
011 2
17
-1
100 2
18
-1
101 2
19
-1
110 2
20
-1
111 2
21
-1
S2 S1 S0 Fosc = 12 MHz Fosc = 16 MHz Fosc = 20 MHz
0 0 0 16.38 ms 12.28 ms 9.82 ms
0 0 1 32.77 ms 24.57 ms 19.66 ms
0 1 0 65.54 ms 49.14 ms 39.32 ms
0 1 1 131.07 ms 98.28 ms 78.64 ms
1 0 0 262.14ms 196.56ms 157.28ms
1 0 1 524.29ms 393.12ms 314.56ms
1 1 0 1.05sec 786.24ms 629.12ms
1 1 1 2.10 sec 1.57 s 1.25 ms