68
T89C51CC01
Rev. D – 17-Dec-01
14.1 WatchDog
Programming
The three lower bits (S0, S1, S2) located into WDTPRG register permit to program the
WDT duration.
Table 32. Machine Cycle Count
To compute WD Time-Out, the following formula is applied:
Note: Svalue represents the decimal value of (S2 S1 S0)
Find Hereafter computed Time-Out value for Fosc
XTAL
= 12MHz in X1 mode
Table 33. Time-Out Computation
14.2 WatchDog Timer
during Power down
mode and Idle
In Power Down mode the oscillator stops, which means the WDT also stops. While in
Power Down mode, the user does not need to service the WDT. There are 2 methods of
exiting Power Down mode: by a hardware reset or via a level activated external interrupt
which is enabled prior to entering Power Down mode. When Power Down is exited with
hardware reset, the watchdog is disabled. Exiting Power Down with an interrupt is signif-
icantly different. The interrupt shall be held low long enough for the oscillator to stabilize.
When the interrupt is brought high, the interrupt is serviced. To prevent the WDT from
resetting the device while the interrupt pin is held low, the WDT is not started until the
S2 S1 S0 Machine Cycle Count
000 2
14
-1
001 2
15
-1
010 2
16
-1
011 2
17
-1
100 2
18
-1
101 2
19
-1
110 2
20
-1
111 2
21
-1
S2 S1 S0 Fosc=12MHz Fosc=16MHz Fosc=20MHz
0 0 0 16.38 ms 12.28 ms 9.82 ms
0 0 1 32.77 ms 24.57 ms 19.66 ms
0 1 0 65.54 ms 49.14 ms 39.32 ms
0 1 1 131.07 ms 98.28 ms 78.64 ms
1 0 0 262.14ms 196.56ms 157.28ms
1 0 1 524.29ms 393.12ms 314.56ms
1 1 0 1.05 s 786.24 ms 629.12 ms
1 1 1 2.10 s 1.57 s 1.25 ms
FTime Out
F
wd
12 2
14
2
Svalue
×()1–()×
-------------------------------------------------------------------
=–