16.3. PCA Capture Mode
To use one of the PCA modules in capture mode either one or both of the CCAPM bits CAPN and CAPP for
that module must be set. The external CEX input for the module (on port 1) is sampled for a transition. When a
valid transition occurs the PCA hardware loads the value of the PCA counter registers (CH and CL) into the
module’s capture registers (CCAPnL and CCAPnH). If the CCFn bit for the module in the CCON SFR and the
ECCFn bit in the CCAPMn SFR are set then an interrupt will be generated.
Figure 106. PCA Capture Mode
CEXn
n = 0, 1
PCA Counter
CH
(8bits)
CL
(8bits)
CCAPnH
CCAPnL
CCFn
CCON Reg
PCA
Interrupt
Request
- 0CAPPnCAPNn000 ECCFn
7
CCAPMn Register (n = 0, 1)