Rainbow-electronics ATA6823 Bedienungsanleitung Seite 7

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 28
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 6
7
4856E–AUTO–07/07
ATA6823 [Preliminary]
Pulling the EN2 pin up to the V
BAT
level will drive the IC into Active mode. EN2 is debounced with
a time constant of 20 µs, based on a 100 kHz clock.
Go to Active using the LIN interface
The second possibility for wake-up can be performed using the LIN transceiver. In Sleep mode,
the LIN receiver is partially active.
The wake-up by LIN requires 2 steps:
1. If the voltage on pin LIN is below a value of V
/DATwake
(about V
VBAT
– 2V) the receive part
of the LIN interface is active (not to be confused with Active mode of the whole IC). The
active receive part is able to detect a valid LOW on the LIN pin.
2. If LIN = LOW during a filter time t
wakeLIN
(typically 70 µs) the IC will change to Active
mode. A short change back to HIGH during the filter time will reset the filter. This infor-
mation is stored in a latch after entering Active mode
If the change to Active mode was caused by LIN, the EN1 or EN2 pins may remain LOW without
disturbing the Active mode.
Stay in Active via EN1
The input EN1 is intended to keep the IC in Active Mode via a signal from the microcontroller.
The input is ESD-protected by diodes against GND and VCC. Therefore, the input voltage must
be positive and not higher than V
CC
. EN1 cannot be used to switch from Sleep to Active because
the VCC regulator is off in the Sleep mode and V
CC
will be zero.
Go to Sleep
A HIGH to LOW transition at pin EN1 and a following permanent LOW for the time t
gotosleep
(typically 20 µs) switches the IC to Sleep mode.
Figure 5-1 illustrates the wake-up by LIN. The status PREWAKE is characterized by the acti-
vated receive block of the LIN interface. After going to Active mode, the V
CC
regulator starts
working.
Go to Sleep is possible with a valid HIGH to LOW transition at pin EN1 (permanent LOW for
longer than t
db
) if EN1 was in a valid HIGH state (HIGH for longer than t
db
) before.