12-Channel/8-Channel, Flash-Configurable System
Managers with Nonvolatile Fault Registers
MAX16065/MAX16066
______________________________________________________________________________________ 57
Register Map (continued)
FLASH
ADDRESS
REGISTER
ADDRESS
READ/
WRITE
DESCRIPTION
278 078 R/W Sequence delay for Slot 2 and Slot 3
279 079 R/W Sequence delay for Slot 4 and Slot 5
27A 07A R/W Sequence delay for Slot 6 and Slot 7
27B 07B R/W Sequence delay for Slot 8 and Slot 9
27C 07C R/W Sequence delay for Slot 10 and Slot 11
27D 07D R/W Primary sequence final slot, sequence delay for Slot 12
MISCELLANEOUS
27E 07E R/W MON1/MON2 slot assignment
27F 07F R/W MON3/MON4 slot assignment
280 080 R/W MON5/MON6 slot assignment
281 081 R/W MON7/MON8 slot assignment
282 082 R/W MON9/MON10 slot assignment
283 083 R/W MON11/MON12 slot assignment
284 084 R/W EN_OUT1/EN_OUT2 slot assignment
285 085 R/W EN_OUT3/EN_OUT4 slot assignment
286 086 R/W EN_OUT5/EN_OUT6 slot assignment
287 087 R/W EN_OUT7/EN_OUT8 slot assignment
288 088 R/W EN_OUT9/EN_OUT10 slot assignment
289 089 R/W EN_OUT11/EN_OUT12 slot assignment
28A 08A R/W Customer use (version)
28B 08B R/W PEC enable/SMBus address
28C 08C R/W Lock bits
28D 08D R Revision code
NONVOLATILE FAULT LOG
200
R/W
Sequence state
201
R/W
Fault flags, MON1–MON8
202
R/W
Fault flags, MON9–MON12, OC, EXTFAULT
203
R/W
MON1 ADC output
204
R/W
MON2 ADC output
205
R/W
MON3 ADC output
206
R/W
MON4 ADC output
207
R/W
MON5 ADC output
208
R/W
MON6 ADC output
209
R/W
MON7 ADC output
20A
R/W
MON8 ADC output
20B
R/W
MON9 ADC output
20C
R/W
MON10 ADC output
20D
R/W
MON11ADC output
20E
R/W
MON12 ADC output
20F
R/W
Current-sense ADC output