DS4560
12V Hot-Plug Switch
2 _______________________________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
RECOMMENDED OPERATING CONDITIONS
(T
J
= -40°C to +135°C.)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
Voltage Range on V
CC
and LOAD Relative to GND
Continuous .........................................................-0.3V to +18V
1ms Maximum ....................................................-0.3V to +22V
Voltage Range on ILIM and VRAMP
Relative to GND.....................................-0.3V to (V
CC
+ 0.3V),
but not to exceed +18V
Voltage Range on TIMER Relative to GND ...........-0.3V to +5.0V
Drain Current
Continuous ...........................................................................4A
Peak ...................................................................................15A
Operating Junction Temperature Range...........-40°C to +135°C
Storage Temperature Range .............................-55°C to +135°C
Soldering Temperature...........................Refer to the IPC/JEDEC
J-STD-020 Specification.
ELECTRICAL CHARACTERISTICS
(V
CC
= +12V, T
J
= +25°C, unless otherwise noted.)