Rainbow-electronics MAX194 Bedienungsanleitung Seite 4

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 24
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 3
MAX194
14-Bit, 85ksps ADC with 10µA Shutdown
4 _______________________________________________________________________________________
VDDD = VDDA = 5.25V, VSSD = VSSA = -5.25V
VDDD = VDDA = 5.25V, VSSD = VSSA = -5.25V,
BP/UP/SHDN = 0V
VDDD = VDDA = 5.25V, VSSD = VSSA = -5.25V,
BP/UP/SHDN = 0V
VDDD = VDDA = 5.25V, VSSD = VSSA = -5.25V,
BP/UP/SHDN = 0V
VDDD = VDDA = 5.25V, VSSD = VSSA = -5.25V,
BP/UP/SHDN = 0V
CONDITIONS
mW80Power Dissipation
µA0.1 5I
SSA
VSSA Shutdown Supply Current
µA0.1 5I
DDA
VDDA Shutdown Supply Current
µA1.6 5I
DDD
VDDD Shutdown Supply Current
(Note 5)
µA0.1 5I
SSD
VSSD Shutdown Supply Current
UNITSMIN TYP MAXSYMBOLPARAMETER
ELECTRICAL CHARACTERISTICS (continued)
(VDDD = VDDA = +5V, VSSD = VSSA = -5V, f
CLK
= 1.7MHz, V
REF
= +5V, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical
values are at T
A
= +25°C.)
TIMING CHARACTERISTICS
(VDDD = VDDA = +5V, VSSD = VSSA = -5V, unless otherwise noted.)
Note 1: Accuracy and dynamic performance tests performed after calibration.
Note 2: Tested with 50% duty cycle. Duty cycles from 25% to 75% at 1.7MHz are acceptable.
Note 3: See
External Clock
section.
Note 4: Guaranteed by design, not tested.
Note 5: Measured in shutdown mode with CLK and SCLK low.
POWER REQUIREMENTS (cont.)
PARAMETER SYMBOL CONDITIONS
T
A
= +25°C
TYP
T
A
= 0°C to
+70°C
MIN MAX
T
A
= -40°C to
+85°C
MIN MAX
T
A
= -55°C to
+125°C
MIN MAX
UNITS
CONV Pulse Width
t
CW
20 30 35 ns
CONV to CLK Falling
Synchronization (Note 4)
t
CC1
10 10 10 ns
CONV to CLK Rising
Synchronization (Note 4)
t
CC2
40 40 ns
Data Access Time t
DV
C
L
= 50pF 80 80
40
ns
Bus Relinquish Time t
DH
C
L
= 10pF 40 40 40 ns
CLK to EOC High
t
CEH
C
L
= 50pF 300 300 350 ns
CLK to EOC Low
t
CEL
C
L
= 50pF 300 300 350 ns
CLK to DOUT Valid t
CD
C
L
= 50pF 100 350 100 375 100 400 ns
SCLK to DOUT Valid t
SD
C
L
= 50pF 20 140 20 160 20 160 ns
CS to SCLK Setup Time
t
CSS
75 75 75 ns
CS to SCLK Hold Time
t
CSH
-10 -10 -10 ns
Acquisition Time t
AQ
2.4 2.4 2.4 µs
Calibration Time t
CAL
14,000(
CLK
) 8.2 8.2 8.2 ms
RESET to CLK Setup Time
t
RCS
-40 -40 -40 ns
RESET to CLK Hold Time
t
RCH
120 120 120
Start-Up Time (Note 6) t
SU
Exiting
shutdown
3.2
ns
90
µs
Note 6: Settling time required after deasserting shutdown to achieve less than 0.1LSB additional error.