MAX5290–MAX5295
Buffered, Fast-Settling, Dual, 12-/10-/8-Bit,
Voltage-Output DACs
20 ______________________________________________________________________________________
CONTROL BITS DATA BITS
DATA
C3 C2 C1 C0 D27 D26 D25 D24 D23 D22 D21 D20 D19 D18 D17 D16 D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
FUNCTION
READ INPUT AND DAC REGISTERS A AND B
DIN 1 1 1 1 0 1 0 X 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 X X X X X X X X
D OU TRB X X X X X X X X D23 D22 D21 D20 D19 D18 D17 D16
D15/
X
D14/
X
D13/
X
D12/
X
D11 D10 D9 D8 D7 D6 D5 D4
D3/
X
D2/
X
D1/
X
D0/
X
Read i np ut
r eg i ster A
and D AC
r eg i ster A
( al l 24
b i ts) .**†
DIN 1 1 1 1 0 1 1 X 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 X X X X X X X X
D OU TRB X X X X X X X X D23 D22 D21 D20 D19 D18 D17 D16
D15/
X
D14/
X
D13/
X
D12/
X
D11 D10 D9 D8 D7 D6 D5 D4
D3/
X
D2/
X
D1/
X
D0/
X
Read i np ut
r eg i ster B
and D AC
r eg i ster B
( al l 24
b i ts) .** †
Table 2c. 24-Bit Read Commands
X = Don’t care.
**D23–D12 represent the 12-bit data from the corresponding DAC register. D11–D0 represent the 12-bit data from the corresponding input register. For
the MAX5292/MAX5293, bits D13, D12, D1, and D0 are don’t-care bits. For the MAX5294/MAX5295, bits D15–D12 and D3–D0 are don’t-care bits.
†
During readback, all ones (code FF) must be clocked into DIN for all 24 bits. No command may be issued before all 24 bits have been clocked out.
CS
must be kept low while all 24 bits are clocked out.
CONTROL BITS DATA BITS
DATA
C3 C2 C1 C0
D1 D1
D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
FUNCTION
UPIO_ AS GPI (GENERAL-PURPOSE INPUT)
DIN1111001XXXXXXXXX
DOUTRB X X X X X X X X X X RTP2 LF2 LR2 RTP1 LF1 LR1
Read UPIO_ inputs. (Valid
only when UPIO1 or
UPIO2 is configured as a
general-purpose input.)
See GPI, GPOL, GPOH
section.
OTHER COMMANDS
DIN 1 1 1 1 1 0 0 X X X X X X X X X Command is ignored.
DIN 1 1 1 1 1 0 1 X X X X X X X X X Command is ignored.
DIN 1 1 1 1 1 1 0 X X X X X X X X X Command is ignored.
DIN 1 1 1 1 1 1 1 0 X X X X X X X X Command is ignored.
DIN 11111111 1 1 1 1 1 1 1 1
16-bit no-op command. All
DACs are unaffected.
Table 2b. Advanced-Feature Programming Commands (continued)
X = Don’t care.