DS2781: Two-Cell Standalone Fuel Gauge IC
10 of 30
ACR register update period). A write to the ACR forces the ADC to perform an offset correction conversion and
update the internal offset correction factor. Current measurement and accumulation begins with the second
conversion following a write to the ACR. Writing ACR clears the fractional values in ACRL. The Format of the ACR
register is shown in Figure 8, and the format of ACRL is shown in Figure 9.
In order to preserve the ACR value in case of power loss, the ACR value is backed up to EEPROM. The ACR
value is recovered from EEPROM on power-up. See the Memory Map in Table 2 for specific address location and
backup frequency.
Figure 8. Accumulated Current Register Format, ACR
ACR
R/W & EE
MSB—Address 10h LSB—Address 11h
2
15
2
14
2
13
2
12
2
11
2
10
2
9
2
8
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
MSb LSb MSb LSb
Units: 6.25mVh/Rsns
Figure 9. Fractional/Low Accumulated Current Register Format, ACRL
ACRL
Read Only
MSB—Address 12h LSB—Address 13h
2
11
2
10
2
9
2
8
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
X X X X
MSb LSb MSb LSb
“X”: reserved Units:1.526nVHr/R
SNS
ACR LSb
R
SNS
VSS
-
VSNS
20m 15m10m 5m
6.25Vh 312.5Ah 416.7Ah 625Ah 1.250mAh
ACR RANGE
R
SNS
VSS
-
VSNS
20m 15m10m 5m
±409.6mVh ±20.48Ah ±27.30Ah ±40.96Ah ±81.92Ah