27
2588B–AVR–11/06
ATtiny261/461/861
Figure 7-3. External Clock Drive Configuration
When this clock source is selected, start-up times are determined by the SUT Fuses as shown in
Table 7-3.
Note that the System Clock Prescaler can be used to implement run-time changes of the internal
clock frequency while still ensuring stable operation. Refer to ”System Clock Prescaler” on page
31 for details.
7.5 High Frequency PLL Clock - PLL
CLK
There is an internal PLL that provides nominally 64 MHz clock rate locked to the RC Oscillator
for the use of the Peripheral Timer/Counter1 and for the system clock source. When selected as
a system clock source, by programming the CKSEL fuses to ‘0001’, it is divided by four like
shown in Table 7-4. When this clock source is selected, start-up times are determined by the
SUT fuses as shown in Table 7-5. See also ”PCK Clocking System” on page 25.
Table 7-3. Start-up Times for the External Clock Selection
SUT1..0
Start-up Time from Power-
down and Power-save
Additional Delay from
Reset Recommended Usage
00 6 CK 14CK BOD enabled
01 6 CK 14CK + 4 ms Fast rising power
10 6 CK 14CK + 64 ms Slowly rising power
11 Reserved
EXTERNAL
CLOCK
SIGNAL
CLKI
GND
Table 7-4. PLLCK Operating Modes
CKSEL3..0 Nominal Frequency
0001 16 MHz
Table 7-5. Start-up Times for the PLLCK
SUT1..0
Start-up Time from Power
Down
Additional Delay from
Reset (V
CC
= 5.0V) Recommended usage
00 1K (1024) + 4 ms 14CK + 4 ms BOD enabled
01 16K (16384) + 4 ms 14CK + 4 ms Fast rising power
10 1K (1024) + 64 ms 14CK + 4 ms Slowly rising power
11 16K (16384) + 64 ms 14CK + 4 ms Slowly rising power